That is not avoidable. The current being drawn by the unit causes a voltage drop in the wires feeding it. The unit is seeing about a volt less than the battery is supplying because of this loss and that's what it displays.
A couple of things follow from this that may interest you. Since the voltage drop is caused by current and the resistance of the wire, if you reduce the current, you'll reduce the drop. You can demonstrate this by changing the backlight brightness on your unit and watching the voltage. With the backlight way down, the voltage reading on the unit will be closer to the actual voltage.
The other interesting thing is that this explains why larger wires are used for applications where you need high current. Your TM wiring may need to handle more than 50A. Heat aside, if you used 18AWG wire to run a 24V TM, you'd get about 10V to your TM. By stepping up to 6AWG, you'd get 24.42V out of the 25.3V your batteries provide. Stepping up to 2AWG would get you 24.97V.
Additionally, every connection in a wire makes the issue worse. Fuse holders, splices, connectors etc. all add loss. Shorter, heavier wires do a better job of providing power to equipment. The voltage that is "lost" in wiring and connections is actually wasted as heat.


Likes:
Thanks:
HaHa: 



Reply With Quote