    All the way to the skeg means drill a small hole thru the skeg and attach the ground wire with a screw or bolt

  2. #12
    Join Date
    Feb 2011
    Location
    kentucky
    Posts
    2,549
    Post Thanks / Like

    Default

    Quote Originally Posted by rdjj71m View Post
    Kosmo, I have a Minn Kota Maxxum with composite shaft and ran my ground to the top of the TM motor "only" helped but still had to add ferrite rings. Not sure I understand the "all the way to the skeg" ?
    I'm not familiar with doing this on a Minn koda. (Maybe better off with ferrite chokes) I don't no.For the best results though, I think there needs to be a ground at the lowest spot on the trolling motor. You can check, by running a continuity test.to see if there's a ground to the skeg

  3. #13
    Join Date
    Feb 2011
    Location
    kentucky
    Posts
    2,549
    Post Thanks / Like

    Default

    On my motorguide xi5, I have continuity from the skeg back to negative of power to sonar or actually all the way back to the batteries.

  4. #14
    Join Date
    Feb 2010
    Location
    Edmond, OK
    Posts
    597
    Post Thanks / Like

    Default

    Kosmo, Ljones, I have a copper blade clamped to the top of the motor and though that should be a good ground all the way to the bottom of the skeg, but will check. The wire is ran all the way back to the TM batteries. Thanks

  5. #15
    Join Date
    Feb 2007
    Posts
    8,237
    Post Thanks / Like

    Default

    Interesting,
    I'm going to reveal my stupidity here but I'd assumed my skeg was some or of composite.
    XI5 = aluminum motor housing , skeg?

    thanks
    G3PO

  6. #16
    Join Date
    Feb 2011
    Location
    kentucky
    Posts
    2,549
    Post Thanks / Like

    Default

    Quote Originally Posted by rdjj71m View Post
    Kosmo, Ljones, I have a copper blade clamped to the top of the motor and though that should be a good ground all the way to the bottom of the skeg, but will check. The wire is ran all the way back to the TM batteries. Thanks
    I still have a little interference, but not bad.i see it on the 800khz.